CIQTEK stellte die CryoHe Kryosonden und CAN S Hochfeld Festkörper NMR Spektrometer am 31. Bei CryoHe wird die Hochfrequenzspule auf etwa 20 K (−253 °C) gekühlt.
Veröffentlicht vonBearbeitet mit GPT-6 LunaBilder erstellt mit GPT Image 2
Forschungsantwort

Create a landscape editorial hero image for this Studio Global article: What did CIQTEK announce at the second Analytical Science and Instrument Conference in Wuhan on October 31, 2026, about its CryoHe cryogenic. Article summary: CIQTEK announced the commercial launch of its CryoHe cryogenic NMR probes and CAN-S high-field solid-state NMR spectrometers at the second Analytical Science and Instrument Conference in Wuhan on October 31, 2026, saying. Topic tags: general, general web, user generated, government, academic. Style: premium digital editorial illustration, source-backed research mood, clean composition, high detail, modern web publication hero. Use reference image context only for broad subject, composition, and topical grounding; do not copy the exact image. Avoid: logos, brand marks, copyrighted characters, real person likenesses, fake screenshots, UI text, readable text, wate
CIQTEK hat am 31. Oktober 2026 auf der zweiten Konferenz für Analytische Wissenschaft und Instrumente in Wuhan zwei NMR-Produkte vorgestellt: die kryogenen CryoHe-Sonden und die CAN-S-Hochfeldspektrometer für Festkörper-NMR. Laut Berichten sind beide Produkte für die Serienfertigung und Auslieferung bereit. Als „erste kommerzielle Produkte ihrer Art aus China“ werden sie in der Berichterstattung zum Start bezeichnet – eine unabhängig bestätigte Prioritätsfeststellung ist das nicht. 1
23
Eine NMR-Sonde enthält die Hochfrequenzspule (HF-Spule) und zugehörige Schaltkreise, mit denen das Signal einer Probe erfasst wird. Diese Bauteile erzeugen selbst thermisches Rauschen, das schwache Signale überdecken kann. Werden sie gekühlt, sinkt dieses Rauschen – und geringe Konzentrationen lassen sich möglicherweise leichter messen. Die Kernspinresonanzspektroskopie (NMR) hilft unter anderem dabei, Molekülstrukturen, die Faltung von Proteinen in Lösung und die Konzentration von Stoffwechselprodukten zu untersuchen. 1
CIQTEK zufolge nutzt CryoHe eine geschlossene Kühlung, um die zentrale HF-Spule auf rund 20 K (−253 °C) zu halten. In den Berichten zur Markteinführung wird eine mehr als dreimal so hohe Empfindlichkeit wie bei einer Sonde mit Raumtemperatur genannt. Die vorliegenden Angaben enthalten jedoch keine Testbedingungen, anhand derer sich der Vergleich unabhängig beurteilen ließe. Auch ein gesonderter Empfindlichkeitswert speziell für ¹H ist damit nicht belegt. 1
29
Die Produktseite des Herstellers nennt folgende Spezifikationen: 29
Eine kryogene Feldstabilisierung beziehungsweise Feldsperre wird in den bereitgestellten technischen Angaben nicht beschrieben. Ob CryoHe eine solche Funktion besitzt, lässt sich daraus daher nicht bestätigen. 29
Bei Flüssigkeits-NMR muss die Probe normalerweise nahe der Raumtemperatur bleiben und darf nicht einfrieren. CIQTEK-Chefingenieur Shi Zhifu beschrieb die technische Herausforderung so: Die HF-Spule soll bei etwa 20 K arbeiten, obwohl sie nur rund 2 mm von der Probe entfernt ist. Zwischen beiden liegen damit auf sehr kurzer Distanz fast 280 °C Temperaturunterschied. 1
23
Laut Berichten zum Produktstart gehören geschlossene Kühlung, vibrationsarme Konstruktion, präzise Temperaturregelung und Vakuumisolierung zum technischen Ansatz. Detaillierte Messwerte etwa zu Wärmeeintrag, Vibrationen oder Temperaturstabilität liegen in den verfügbaren Berichten jedoch nicht vor. Wie gut die einzelnen Maßnahmen in der Praxis funktionieren, lässt sich deshalb nicht unabhängig bewerten. 36
Berichten zufolge ist CAN-S ein kommerzielles Hochfeld-Festkörper-NMR-Spektrometer. Es soll Untersuchungen der lokalen Struktur, der Koordinationsumgebung, von Grenzflächenzuständen und molekularen Bewegungen in festen Materialien ermöglichen. 39
Ein Bericht über einen Austausch mit Fachleuten nennt 9,4- und 14,1-T-Magnete sowie Rotoren mit Durchmessern von 3,2, 4 und 7 mm. Für den 3,2-mm-Rotor wird eine maximale Drehzahl von 24 kHz angegeben. Laut demselben Bericht kann CAN-S auch für Flüssigkeits-NMR eingesetzt werden; die verfügbaren Informationen erläutern jedoch nicht, mit welchen Konfigurationen oder unter welchen Bedingungen. 24
Weitere Berichte nennen Batteriematerialien, Mehrphasen-Katalyse und Polymere als mögliche Forschungsfelder. Konkrete Leistungsnachweise für Batterieelektroden, Festelektrolyte, Arzneimittelkristalle oder Verbundwerkstoffe lassen sich aus den vorliegenden Angaben nicht ableiten. 27
Laut Berichten zur Markteinführung wurde der Markt für hochwertige kryogene NMR-Sonden bislang von wenigen Herstellern aus Deutschland und Japan geprägt. Für chinesische Labore seien damit eine Abhängigkeit von Importen, lange Beschaffungszeiten, hohe Anschaffungs- und Wartungskosten sowie Einschränkungen beim technischen Kundendienst verbunden gewesen. Die neuen Geräte wurden als inländische Alternativen bei Kryosonden und Festkörper-NMR-Systemen präsentiert. 34
Damit könnte Labors eine weitere Bezugsquelle zur Verfügung stehen. Belegt ist bislang jedoch nicht, dass die Markteinführung Preise senkt, Lieferzeiten verkürzt oder die Gesamtkosten über die Nutzungsdauer reduziert. Auch die weitergehende Erwartung, eine heimische Versorgung schaffe eine nachhaltigere Lieferkette, ist durch die vorliegenden Informationen nicht bestätigt.
Studio Global AI
Diese Seite enthält eine quellengestützte Antwort, die Sie in Studio Global fortsetzen können.
CIQTEK stellte die CryoHe Kryosonden und CAN S Hochfeld Festkörper NMR Spektrometer am 31.
CIQTEK stellte die CryoHe Kryosonden und CAN S Hochfeld Festkörper NMR Spektrometer am 31. Bei CryoHe wird die Hochfrequenzspule auf etwa 20 K (−253 °C) gekühlt. Der Hersteller nennt unter anderem die Kompatibilität mit CAN Systemen, fünf beobachtbare Atomkerne und eine Z Gradientenstärke von mindestens 50...
Für CAN S werden Magnetfelder von 9,4 und 14,1 T genannt. Die Bezeichnung als erste kommerzielle Produkte ihrer Art aus China ist eine Launch Aussage und kein unabhängig bestätigter Prioritätsnachweis.
CIQTEK stellte die CryoHe Kryosonden und CAN S Hochfeld Festkörper NMR Spektrometer am 31. Bei CryoHe wird die Hochfrequenzspule auf etwa 20 K (−253 °C) gekühlt.
Veröffentlicht vonBearbeitet mit GPT-6 LunaBilder erstellt mit GPT Image 2
Forschungsantwort

Create a landscape editorial hero image for this Studio Global article: What did CIQTEK announce at the second Analytical Science and Instrument Conference in Wuhan on October 31, 2026, about its CryoHe cryogenic. Article summary: CIQTEK announced the commercial launch of its CryoHe cryogenic NMR probes and CAN-S high-field solid-state NMR spectrometers at the second Analytical Science and Instrument Conference in Wuhan on October 31, 2026, saying. Topic tags: general, general web, user generated, government, academic. Style: premium digital editorial illustration, source-backed research mood, clean composition, high detail, modern web publication hero. Use reference image context only for broad subject, composition, and topical grounding; do not copy the exact image. Avoid: logos, brand marks, copyrighted characters, real person likenesses, fake screenshots, UI text, readable text, wate
CIQTEK hat am 31. Oktober 2026 auf der zweiten Konferenz für Analytische Wissenschaft und Instrumente in Wuhan zwei NMR-Produkte vorgestellt: die kryogenen CryoHe-Sonden und die CAN-S-Hochfeldspektrometer für Festkörper-NMR. Laut Berichten sind beide Produkte für die Serienfertigung und Auslieferung bereit. Als „erste kommerzielle Produkte ihrer Art aus China“ werden sie in der Berichterstattung zum Start bezeichnet – eine unabhängig bestätigte Prioritätsfeststellung ist das nicht. 1
23
Eine NMR-Sonde enthält die Hochfrequenzspule (HF-Spule) und zugehörige Schaltkreise, mit denen das Signal einer Probe erfasst wird. Diese Bauteile erzeugen selbst thermisches Rauschen, das schwache Signale überdecken kann. Werden sie gekühlt, sinkt dieses Rauschen – und geringe Konzentrationen lassen sich möglicherweise leichter messen. Die Kernspinresonanzspektroskopie (NMR) hilft unter anderem dabei, Molekülstrukturen, die Faltung von Proteinen in Lösung und die Konzentration von Stoffwechselprodukten zu untersuchen. 1
CIQTEK zufolge nutzt CryoHe eine geschlossene Kühlung, um die zentrale HF-Spule auf rund 20 K (−253 °C) zu halten. In den Berichten zur Markteinführung wird eine mehr als dreimal so hohe Empfindlichkeit wie bei einer Sonde mit Raumtemperatur genannt. Die vorliegenden Angaben enthalten jedoch keine Testbedingungen, anhand derer sich der Vergleich unabhängig beurteilen ließe. Auch ein gesonderter Empfindlichkeitswert speziell für ¹H ist damit nicht belegt. 1
29
Die Produktseite des Herstellers nennt folgende Spezifikationen: 29
Eine kryogene Feldstabilisierung beziehungsweise Feldsperre wird in den bereitgestellten technischen Angaben nicht beschrieben. Ob CryoHe eine solche Funktion besitzt, lässt sich daraus daher nicht bestätigen. 29
Bei Flüssigkeits-NMR muss die Probe normalerweise nahe der Raumtemperatur bleiben und darf nicht einfrieren. CIQTEK-Chefingenieur Shi Zhifu beschrieb die technische Herausforderung so: Die HF-Spule soll bei etwa 20 K arbeiten, obwohl sie nur rund 2 mm von der Probe entfernt ist. Zwischen beiden liegen damit auf sehr kurzer Distanz fast 280 °C Temperaturunterschied. 1
23
Laut Berichten zum Produktstart gehören geschlossene Kühlung, vibrationsarme Konstruktion, präzise Temperaturregelung und Vakuumisolierung zum technischen Ansatz. Detaillierte Messwerte etwa zu Wärmeeintrag, Vibrationen oder Temperaturstabilität liegen in den verfügbaren Berichten jedoch nicht vor. Wie gut die einzelnen Maßnahmen in der Praxis funktionieren, lässt sich deshalb nicht unabhängig bewerten. 36
Berichten zufolge ist CAN-S ein kommerzielles Hochfeld-Festkörper-NMR-Spektrometer. Es soll Untersuchungen der lokalen Struktur, der Koordinationsumgebung, von Grenzflächenzuständen und molekularen Bewegungen in festen Materialien ermöglichen. 39
Ein Bericht über einen Austausch mit Fachleuten nennt 9,4- und 14,1-T-Magnete sowie Rotoren mit Durchmessern von 3,2, 4 und 7 mm. Für den 3,2-mm-Rotor wird eine maximale Drehzahl von 24 kHz angegeben. Laut demselben Bericht kann CAN-S auch für Flüssigkeits-NMR eingesetzt werden; die verfügbaren Informationen erläutern jedoch nicht, mit welchen Konfigurationen oder unter welchen Bedingungen. 24
Weitere Berichte nennen Batteriematerialien, Mehrphasen-Katalyse und Polymere als mögliche Forschungsfelder. Konkrete Leistungsnachweise für Batterieelektroden, Festelektrolyte, Arzneimittelkristalle oder Verbundwerkstoffe lassen sich aus den vorliegenden Angaben nicht ableiten. 27
Laut Berichten zur Markteinführung wurde der Markt für hochwertige kryogene NMR-Sonden bislang von wenigen Herstellern aus Deutschland und Japan geprägt. Für chinesische Labore seien damit eine Abhängigkeit von Importen, lange Beschaffungszeiten, hohe Anschaffungs- und Wartungskosten sowie Einschränkungen beim technischen Kundendienst verbunden gewesen. Die neuen Geräte wurden als inländische Alternativen bei Kryosonden und Festkörper-NMR-Systemen präsentiert. 34
Damit könnte Labors eine weitere Bezugsquelle zur Verfügung stehen. Belegt ist bislang jedoch nicht, dass die Markteinführung Preise senkt, Lieferzeiten verkürzt oder die Gesamtkosten über die Nutzungsdauer reduziert. Auch die weitergehende Erwartung, eine heimische Versorgung schaffe eine nachhaltigere Lieferkette, ist durch die vorliegenden Informationen nicht bestätigt.
Studio Global AI
Diese Seite enthält eine quellengestützte Antwort, die Sie in Studio Global fortsetzen können.
CIQTEK stellte die CryoHe Kryosonden und CAN S Hochfeld Festkörper NMR Spektrometer am 31.
CIQTEK stellte die CryoHe Kryosonden und CAN S Hochfeld Festkörper NMR Spektrometer am 31. Bei CryoHe wird die Hochfrequenzspule auf etwa 20 K (−253 °C) gekühlt. Der Hersteller nennt unter anderem die Kompatibilität mit CAN Systemen, fünf beobachtbare Atomkerne und eine Z Gradientenstärke von mindestens 50...
Für CAN S werden Magnetfelder von 9,4 und 14,1 T genannt. Die Bezeichnung als erste kommerzielle Produkte ihrer Art aus China ist eine Launch Aussage und kein unabhängig bestätigter Prioritätsnachweis.